Maleic anhydride |
CAS 108-31-6 | ||
C4H2O3 |
RTECS ON3675000 | ||
Synonyms & Trade Names cis-Butenedioic anhydride; 2,5-Furanedione; Maleic acid anhydride; Toxilic anhydride |
DOT ID & Guide 2215 156 |
Exposure
|
NIOSH REL: TWA 1 mg/m3 (0.25 ppm) | ||
OSHA PEL: TWA 1 mg/m3 (0.25 ppm) | |||
IDLH 10 mg/m3 See: 108316 | Conversion 1 ppm = 4.01 mg/m3 |
Physical Description Colorless needles, white lumps, or pellets with an irritating, choking odor. |
|||
MW: 98.1 |
BP: 396°F |
MLT: 127°F |
Sol: Reacts |
VP: 0.2 mmHg |
IP: 9.90 eV |
|
Sp.Gr: 1.48 |
Fl.P: 218°F |
UEL: 7.1% |
LEL: 1.4% |
|
Combustible Solid, but may be difficult to ignite. | |||
Incompatibilities & Reactivities Strong oxidizers, water, alkalis, metals, caustics & amines above 150°F [Note: Reacts slowly with water (hydrolyzes) to form maleic acid.] |
Measurement Methods NIOSH 3512; OSHA 25, 86 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation Provide: Eyewash |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 10 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode£ (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion, skin and/or eye contact | |
Symptoms Irritation nose, upper respiratory system; conjunctivitis; photophobia (abnormal visual intolerance to light), double vision; bronchial asthma; dermatitis | |
Target Organs
Eyes, skin, respiratory system |