alpha-Methyl styrene |
CAS 98-83-9 | ||
C6H5C(CH3)=CH2 |
RTECS WL5075300 | ||
Synonyms & Trade Names AMS, Isopropenyl benzene, 1-Methyl-1-phenylethylene, 2-Phenyl propylene |
DOT ID & Guide |
Exposure
|
NIOSH REL: TWA 50 ppm (240 mg/m3) ST 100 ppm (485 mg/m3) | ||
OSHA PEL†: C 100 ppm (480 mg/m3) | |||
IDLH 700 ppm See: 98839 | Conversion 1 ppm = 4.83 mg/m3 |
Physical Description Colorless liquid with a characteristic odor. |
|||
MW: 118.2 |
BP: 330°F |
FRZ: -10°F |
Sol: Insoluble |
VP: 2 mmHg |
IP: 8.35 eV |
|
Sp.Gr: 0.91 |
Fl.P: 129°F |
UEL: 6.1% |
LEL: 1.9% |
|
Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F. | |||
Incompatibilities & Reactivities Oxidizers, peroxides, halogens, catalysts for vinyl or ionic polymers; aluminum, iron chloride, copper [Note: Usually contains an inhibitor such as tert-butyl catechol.] |
Measurement Methods NIOSH 1501; OSHA 7 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Water flush promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH Up to 500 ppm: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)* (APF = 10) Any supplied-air respirator* Up to 700 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, nose, throat; drowsiness; dermatitis | |
Target Organs
Eyes, skin, respiratory system, central nervous system |
See also: INTRODUCTION See ICSC CARD: 0732 See MEDICAL TESTS: 0257 |