NIOSH Pocket Guide to Chemical Hazards

Azinphos-methyl

CAS 86-50-0

C10H12O3PS2N3

RTECS TE1925000
Synonyms & Trade Names
O,O-Dimethyl-S-4-oxo-1,2,3-benzotriazin-3(4H)-ylmethyl phosphorodithioate; Guthion®; Methyl azinphos
DOT ID & Guide
2783 152(organophosphorus pesticide, solid, toxic)

Exposure
Limits

NIOSH REL: TWA 0.2 mg/m3 [skin]
OSHA PEL: TWA 0.2 mg/m3 [skin]
IDLH 10 mg/m3 See: 86500 Conversion
Physical Description
Colorless crystals or a brown, waxy solid. [insecticide]
MW: 317.3
BP: Decomposes
MLT: 163°F
Sol: 0.003%
VP: 8 x 10-9 mmHg
IP: ?

Sp.Gr: 1.44
Fl.P: NA
UEL: NA
LEL: NA

Noncombustible Solid
Incompatibilities & Reactivities
Strong oxidizers, acids
Measurement Methods
NIOSH 5600; OSHA PV2087
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily
Provide: Quick drench
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash immediately
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 2 mg/m3:
(APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.
Up to 10 mg/m3:
(APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms Miosis; ache eyes; blurred vision, lacrimation (discharge of tears), rhinorrhea (discharge of thin mucus); headache; tightness chest, wheezing, laryngeal spasm; salivation; cyanosis; anorexia; nausea, vomiting, diarrhea; sweating; twitching, paralysis, convulsions; low blood pressure, cardiac irregularities
Target Organs respiratory system, central nervous system, cardiovascular system, blood cholinesterase
See also: INTRODUCTION   See ICSC CARD: 0826   See MEDICAL TESTS: 0020