1. Introduction
1.1 Scope
This method describes
the collection and analysis of airborne trichloroisocyanuric acid and
sodium dichloroisocyanuric acid. The analysis is based on an iodometric
technique utilizing an ion specific electrode.
1.2
Synonyms
1.2.1 Trichloroisocyanuric
acid
TCCA 1,3,5,-Trichloro-s-Triazine-2,4,6-trione
Trichloroiminocyanuric acid ACL-85 Chloral
1.2.2
Sodium Dichloroisocyanuric
acid
DCCA Dichloro-s-triazine-2,4,6-(IH, 3H,
5H)-trione sodium
derivative 3,5-dichlorotetrahydro-2,4,6,-trioxo-striazin-1(2H)-yl
sodium sodium troclorene sodium
dichloroisocyanurate ACL-59 1.3 Uses
Trichloroisocyanuric acid and
dichloroisocyanuric acid are used as a source of available chlorine in
"dry type" bleaches, scouring powders, dishwashing compounds, and
sanitizing compounds.
1.4 Physical and Chemical
Properties
The physical and chemical properties of trichloro and
dichloro isocyanuric acids are:
1.4.1 Trichloroisocyanuric acid -
C3Cl3N3O3; mole. wt.
232.42. C 15-50%, Cl 45.77%, N 18.08%, 0 20.65%. Prepared by
chlorinating cyanuric acid in 5% NaOH solution: Hands, Whitt., Soc.
Chem. Ind. 67,66 (1948); Hardy U.S. pat. 2,607,738 (1952 to Monsanto).
Purification by dissolving in conc. H2SO4 and
diluting with ice water: Lorenz, U.S. pat. 2,828,308 (1958 to Purex
Corp.). May be stored in the dry state for at least a year. Releases
hypochlorous acid on contact with water. Available chlorine about 90%.
pH of aqueous soln. about 4.4. Solubility in water at 25oC
about 0.2%. Soluble in chlorinated and highly polar
solvents.
1.4.2 Dichloroisocyanuric acid -
C3Cl2NaN3O3; mole. wt.
236.06. C 15.26%, Cl 30.04%, Na 16.56%, N 17.80%, 0 20.33%. Structure
studies and preparation: Petterson et.al., J. Org. Chem. 25, 1595
(1960). Preparation from trisodium isocyanurate and gaseous Cl: Symes
et.al., U.S. pats. 3,035,056 and 3,035,057 (1962 to Monsanto).
2. Range and Detection Limit
A lower analytical limit of 0.1 mg/mL, was selected for routine
analysis.
3. Precision and Accuracy:
Within the operating
range of the electrode, reproducibility is reported to be independent of
concentration. With calibration every two hours, electrode measurements
can be obtained which are reproducible to 2%.
4.
Interferences
Strong oxidizing agents including iodate, bromine,
cupric ion and manganese dioxide reportedly interfere with the analysis.
It is also reported that silver and mercuric ion concentrations in the
sample must be below 10 to 20 ppm or they will also interfere with the
analysis.
5. Collection and Shipping of Samples
5.1 Assemble the filter in the
three-piece filter cassette holder and close firmly to insure that the
center ring seals the edge of the filter. The glass fiber filter is
supported with a second glass fiber filter if necessary and the filter
holder is held together by plastic tape or a shrinkable cellulose band.
If the filter does not lie flat and the spacer ring does not fit snugly
into the bottom of the filter holder, sample leakage will occur around
the filter. Remove the cassette plugs. Use pieces of flexible tubing to
connect the filter holder to the impinger and the impinger to the pump.
Fill the impinger with 10 mL of 0.1% sulfamic acid as in the procedure
for Chlorine (ID-101).
5.2 Clip the collection devices to the
worker's lapel. Air being sampled should not be passed through any hose
or tubing before entering the filter cassette.
5.3 A sample size
of 240 liters is recommended. Sample at a flow rate of 1 liter per
minute for 4 hours. The flow rate should be known with an accuracy of at
least ± 5%.
5.4 Turn the pump on and begin sample collection.
Since it is possible for filters to become plugged by heavy particulate
loading or by the presence of oil mists or other liquids in the air, the
pump rotameter should be observed frequently, and the sampling should be
terminated at any evidence of a problem.
5.5 Terminate sampling
at the predetermined time and note sample flow rate, collection time,
and ambient temperature and pressure. If a pressure reading is
unavailable, record the elevation. Replace the filter plugs.
5.6
Transfer the solutions in the midget glass impingers to 20 mL
scintillation vials which have caps with Teflon liners. Cap the vials
and seal the caps with tape. Wrap the tape around the cap in the
direction the cap is turned.
5.7 Blank. With each batch of ten
samples, submit one filter from the same lot of filters which was used
for sample collection and which is subjected to the same handling as for
the samples except that no air is drawn through it. Also submit a sample
of the unused sulfamic acid as in the procedure for Chlorine. Label
these as blanks.
5.8 The sample vials and cassettes are sealed
with OSHA Form 21.
5.9 The sample vials and cassettes are packed
and shipped to the laboratory for analysis as soon as possible.
6. Analytical Procedure
6.1 Apparatus
6.1.1 Sample Collection
Glass
fiber filters, Gelman A/E, 37-mm in diameter. Plastic three piece
37-mm filter holders (cassettes). The filter is supported in the
cassette by a second glass fiber filter if necessary. A personal
air sampling pump capable of operating at 1.5 to 2.0
liters/min.
Midget fritted glass impingers.
6.1.2
Sample Analysis
Orion Model 97-70 residual chlorine electrode
or equivalent Millivolt meter - Orion Model 940 or equivalent
Laboratory glassware including volumetric flasks, pipettes, beakers,
disposable beakers, etc. 6.2.
Reagents
All reagents used should be ACS analyzed reagent grade
or better.
6.2.1 Sulfamic acid,
0.1%
Sulfamic acid (1.0 g) is dissolved in deionized water and
the solution is diluted to one liter.
6.2.2 Potassium iodide,
0.5 M
Potassium iodide (21.75 g) is dissolved in deionized
water and the solution is diluted to 250 mL. The solution should be
made fresh the day it is used.
6.2.3 Acid reagent (buffer) (6.4
M acetic acid, 1.8 M sodium acetate)
Sodium acetate (37.1 g) is
dissolved in 100 mL of deionized water. Glacial acetic acid (92 mL) is
added and the solution is diluted to 250 mL using deionized
water.
6.2.4 Standard Stock Solution
Potassium iodate
(0.500 g) is dissolved in deionized water and diluted to 500 mL in a
volumetric flask. This solution is equivalent to 1000 ppm
chlorine.
6.2.5 TCCA Stock Solution
(optional)
Trichloroisocyanuric acid (0.500 g) is dissolved in
deionized water and diluted to 500 mL in a volumetric flask. This
solution is 1000 ppm TCCA and 915 ppm chlorine.
6.2.6 DCCA
Stock Solution (optional)
Dichloroisocyanuric acid (0.500 g) is
dissolved in deionized water and diluted to 500 mL in a volumetric
flask. This solution is 1000 ppm DCCA and 645 ppm DCCA
chlorine. 6.3 Safety
Precautions
6.3.1 Extreme care must be used when
handling glacial acetic acid. Gloves and face protection should be
used. The area where the acid is diluted should be well ventilated
(NOTE: Do not vent into hoods designated for perchloric acid
Inhalation of the acetic acid vapors should be avoided.) The glacial
acetic acid should be added to the aqueous solution, thus avoiding the
splattering which can occur when water is added to a concentrated
acid. If any of the acid contacts the eyes, skin, or clothes, flush
the area immediately with copious amounts of water. Inform your
supervisor. Medical treatment may be necessary if the burn is
serious.
6.3.2 Care should be exercised when using laboratory
glassware. Chipped pipettes, volumetric flasks, beakers, or any
glassware with sharp edges exposed should not be used in order to
avoid the possibility of cuts or abrasions.
6.3.3 Pipetting is
always done using a pipetting bulb, never by
mouth. 6.4 Standard
Preparation*
6.4.1 The 1000 ppm standard stock
solution is diluted by serial 1/10 dilutions to 100 and 10 ppm working
stock solutions using deionized water.
6.4.2 Standards are
prepared in the analytical range of 20 to 0.2 ppm, using the dilution
scheme indicated in Table 1, by using the following procedure:
6.4.2.1 An aliquot of the indicated
stock solution (Table 1) is placed into a 50 mL volumetric flask. *
NOTE: If available, TCCA or DCCA may be substituted for KI03 and the
results read in direct concentration.
6.4.2.2 Add 0.5 mL acid
reagent to the volumetric flask.
6.4.2.3 Add 0.5 mL potassium
iodide to the volumetric flask and swirl to mix the reagents; allow
the solution to react for 2 minutes before proceeding with the
procedure.
6.4.2.4 Dilute to volume with deionized water; mix
by inverting the flask several times and store in the dark until it
is time to perform the analysis. 6.5 Sample Preparation
6.5.1 Samples are prepared for
analysis by the following procedure:
6.5.1.1 Place glass fiber filter
into conical beaker. Desorb with 40 mL of 0.1% sulfamic
acid.
6.5.1.2 Remove 20 mL (or one-half) and place into 50 mL
volumetric flask, saving the remainder in case a dilution is
necessary.
6.5.1.3 Measure the volume of solution received
and record this volume in your notebook.
6.5.1.4
Quantitatively transfer the sample to a 25 mL volumetric flask.
Rinses for the transfer and final dilutions are made with 0.1%
sulfamic acid.
6.5.1.5 Add 0.5 mL acid reagent to the
volumetric flask.
6.5.1.6 Add 0.5 mL potassium iodide to the
volumetric flask and swirl to mix; allow the solution to react for
two minutes before proceeding with the
procedure.
6.5.1.7 Dilute the sample to volume using
deionized water; mix thoroughly by inverting the flask several times
and store in the dark until it is time to perform the analysis.
Record this volume as the solution
volume. 6.6
Analysis
6.6.1 Analyze the impinger samples as
Chlorine following ID-101.
6.6.2 Working standard solutions are
prepared as previously indicated. (Standards are prepared the day the
analysis is to be performed.)
6.6.3 After inserting the
electrode leads into the appropriate jacks in the millivolt meter, the
instrument is set up for the analysis by following the manufacturers'
instructions. For the Orion 940 the operating instructions are
included in Table 2.
6.6.4 Generally five or six samples are
prepared at a time and are read while preparing the next five or six
samples. The electrode should be rinsed using deionized water and
blotted dry before it is introduced into the next sample or standard
solution. Standard solutions are kept in volumetric flasks in the
dark. Fresh aliquots are used from the volumetric flasks each time a
standard is read. Standards in the range of the samples are read after
every fourth or fifth sample. 6.7 Calculations
6.7.1 The OSHA Auto AA program is used
for the calculations.
6.7.2 Calculations are made using the
following equation:
mg/m3 = |
(ppm sample - ppm blank)(mL
sample vol)(50 mL)
Air volume [liters](mL aliquot
analyzed) | 6.7.4 If
determining TCCA or DCCA with KI03 standards, use the following
equation(s):
TCCA mg/m3 = |
(ppm sample - ppm blank)(mL
sample vol)(50 mL)
Air volume [liters](mL aliquot
analyzed)(0.915)* |
DCCA mg/m3 = |
(ppm sample - ppm blank)(mL
sample vol)(50 mL)
Air volume [liters](mL aliquot
analyzed)(0.645)** |
* TCCA acts as a 91.5%
chlorinating agent. |
**DCCA acts as a 64.5%
chlorinating agent. |
TABLE 1 |
Standard Preparation
Dilution Scheme |
|
STD (PPM) |
mL Stock Used |
Concentration
(ppm) Stock |
Final Vol (mL) |
|
0.2 |
|
1.0 |
|
1.0 |
|
50 |
0.6 |
|
3.0 |
|
3.0 |
|
50 |
1.0 |
|
5.0 |
|
5.0 |
|
50 |
10.0 |
|
5.0 |
|
5.0 |
|
50 |
20.0 |
|
10.0 |
|
10.0 |
|
50 |
TABLE 2 |
Operating
instructions for the Orion 940 Ionanalyzer |
The Orion 940
follows a menu driven display. The instrument is programmed for
the analysis by following the promptings of the menu driven
display using the "YES", "NO" and the numeric keypads to answer
the questions. |
|
OPERATOR
MENU?
|
Answer
"YES".
|
|
CHANGE
ELECTRODE ID?
|
Answer
"YES".
|
|
|
|
|
ELECTRODE 1
= F¯ IS THIS CORRECT?
|
Answer "NO". An
array of four choices will be displayed. Continue to press "NO"
until Cl2 is displayed and then press the number displayed for Cl2
on the numeric keyboard.
|
|
SET NUMBER
OF DECIMAL PLACES OR SIGNIFICANT DIGITS?
|
Answer "NO" or reset
with the numeric keys.
|
|
|
|
SET ABSOLUTE OR
RELATIVE MILLIVOLTS? |
Answer
"NO". |
|
CHANGE THE pH OR ISE
LIMITS?
|
Answer "NO".
|
|
SET
TIMER?
|
Answer
"NO".
|
|
CHANGE PRINT
INTERVAL?
|
Answer
"NO".
|
|
SET
TEMPERATURE?
|
Answer
"NO".
|
|
CHANGE THE
DATE AND TIME?
|
Answer "NO" or
reset with the numeric keys.
|
|
ENTER
STANDBY MODE?
|
Answer
"NO".
|
|
Enter
"speed 0" to continue after changing the electrode ID, if
necessary, and making any other desired changes on the Operator
Menu.
|
|
CALIBRATE
C12?
|
Answer
"YES".
|
|
CALIBRATE BY
DIRECT MEASUREMENT?
|
Answer
"YES".
|
|
ENTER NUMBER
OF STANDARDS (1-5)
|
Press "2" to
calibrate on the 1 and 10 ppm standards.
|
|
DO BLANK
CORRECTION?
|
Answer
"NO".
|
|
1-Cl2
ELECTRODE IN STANDARD 1?
|
The electrode is
rinsed, blotted dry and placed into the 1.0 ppm standard solution
(20 mL disposable plastic beakers are used to hold the solutions).
Answer "YES".
|
|
Std 1 = X.XX
NOT READY
|
Wait for the
reading to stabilize and the display to read ...
|
|
STD 1 = X.XX
CAL AS X.XX?
|
If necessary use
the numeric keys to change to CAL AS 1.00? and answer "YES".
Record this reading in your notebook. |
|
1-Cl2
ELECTRODE IN STD 2?
|
The electrode is
removed from the 1.0 ppm solution, rinsed with deionized water,
and blotted dry. Then the electrode is placed into the 10 ppm
solution. Answer "YES".
|
|
STD 2 =
XX.XX CAL AS XX.XX? |
If necessary
change the XX.XX to 10.00 and answer "YES". Record this reading in
your notebook.
|
|
SLOPE =
-59.2
|
Record the slope
in your notebook.
|
|
MEASURE
1-Cl2? |
|
10:31
11-22-88
|
Answer "YES".
Rinse the electrodes, blot dry and place the electrodes into the
first standard.
|
|
1-Cl2 = X.XX
|
|
10:32
11-22-88 |
Record this
value with the proper sample or standard number. Rinse and dry the
electrodes and repeat this step for each sample or standard. After
all of the analyses are complete enter "speed 8" to return to
ENTER STANDBY? and answer
"YES". | |