NIOSH Pocket Guide to Chemical Hazards

Warfarin

CAS 81-81-2

C19H16O4

RTECS GN4550000
Synonyms & Trade Names
3-(alpha-Acetonyl)-benzyl-4-hydroxycoumarin, 4-Hydroxy-3-(3-oxo-1-phenyl butyl)-2H-1-benzopyran-2-one, WARF
DOT ID & Guide

Exposure
Limits

NIOSH REL: TWA 0.1 mg/m3
OSHA PEL: TWA 0.1 mg/m3
IDLH 100 mg/m3 See: 81812 Conversion
Physical Description
Colorless, odorless, crystalline powder. [rodenticide]
MW: 308.3
BP: Decomposes
MLT: 322°F
Sol: 0.002%
VP(71°F): 0.09 mmHg
IP: ?

Sp.Gr: ?
Fl.P: ?
UEL: ?
LEL: ?

Combustible Solid
Incompatibilities & Reactivities
Strong oxidizers
Measurement Methods
NIOSH 5002
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: No recommendation
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily

First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 0.5 mg/m3:
(APF = 5) Any quarter-mask respirator. Click here for information on selection of N, R, or P filters.
Up to 1 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 2.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter.
Up to 5 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 100 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms Hematuria (blood in the urine), back pain; hematoma arms, legs; epistaxis (nosebleed), bleeding lips, mucous membrane hemorrhage; abdominal pain, vomiting, fecal blood; petechial rash; abnormal hematologic indices
Target Organs Blood, cardiovascular system
See also: INTRODUCTION   See ICSC CARD: 0821   See MEDICAL TESTS: 0242