Stoddard solvent |
CAS 8052-41-3 | ||
|
RTECS WJ8925000 | ||
Synonyms & Trade Names Dry cleaning safety solvent, Mineral spirits, Petroleum solvent, Spotting naphtha [Note: A refined petroleum solvent with a flash point of 102-110°F, boiling point of 309-396°F, and containing >65% C10 or higher hydrocarbons.] |
DOT ID & Guide 1268 128 (petroleum distillates, n.o.s.) |
Exposure
|
NIOSH REL: TWA 350 mg/m3 C 1800 mg/m3 [15-minute] | ||
OSHA PEL†: TWA 500 ppm (2900 mg/m3) | |||
IDLH 20,000 mg/m3 See: 8052413 | Conversion |
Physical Description Colorless liquid with a kerosene-like odor. |
|||
MW: Varies |
BP: 309-396°F |
FRZ: ? |
Sol: Insoluble |
VP: ? |
IP: ? |
|
Sp.Gr: 0.78 |
Fl.P: 102-110°F |
UEL: ? |
LEL: ? |
|
Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F. | |||
Incompatibilities & Reactivities Strong oxidizers |
Measurement Methods NIOSH 1550 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH Up to 3500 mg/m3: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)* (APF = 10) Any supplied-air respirator* Up to 8750 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)* Up to 17,500 mg/m3: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 20,000 mg/m3: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, nose, throat; dizziness; dermatitis; chemical pneumonitis (aspiration liquid); in animals: kidney damage | |
Target Organs
Eyes, skin, respiratory system, central nervous system, kidneys |
See also: INTRODUCTION See ICSC CARD: 0361 See MEDICAL TESTS: 0212 |