Ronnel |
CAS 299-84-3 | ||
(CH3O)2P(S)OC6H2Cl3 |
RTECS TG0525000 | ||
Synonyms & Trade Names O,O-Dimethyl O-(2,4,5-trichlorophenyl) phosphorothioate; Fenchlorophos |
DOT ID & Guide |
Exposure
|
NIOSH REL: TWA 10 mg/m3 | ||
OSHA PEL†: TWA 15 mg/m3 | |||
IDLH 300 mg/m3 See: 299843 | Conversion |
Physical Description White to light-tan, crystalline solid. [insecticide] [Note: A liquid above 106°F.] |
|||
MW: 321.6 |
BP: Decomposes |
MLT: 106°F |
Sol(77°F): 0.004% |
VP(77°F): 0.0008 mmHg |
IP: ? |
|
Sp.Gr(77°F): 1.49 |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Noncombustible Solid | |||
Incompatibilities & Reactivities Strong oxidizers |
Measurement Methods NIOSH 5600; OSHA PV2054 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: Daily |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH Up to 100 mg/m3: (APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters. (APF = 10) Any supplied-air respirator Up to 250 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter. Up to 300 mg/m3: (APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion, skin and/or eye contact | |
Symptoms In animals: irritation eyes; cholinesterase inhibition; liver, kidney damage | |
Target Organs
Eyes, liver, kidneys, blood plasma |
See also: INTRODUCTION See ICSC CARD: 0975 |