Phenyl ether-biphenyl mixture (vapor) |
CAS 8004-13-5 | ||
C6H5OC6H5/C6H5C6H5 |
RTECS DV1500000 | ||
Synonyms & Trade Names Diphenyl oxide-diphenyl mixture; Dowtherm® A |
DOT ID & Guide |
Exposure
|
NIOSH REL: TWA 1 ppm (7 mg/m3) | ||
OSHA PEL: TWA 1 ppm (7 mg/m3) | |||
IDLH 10 ppm See: 8004135 | Conversion 1 ppm = 6.79 mg/m3 (approx) |
Physical Description Colorless to straw-colored liquid or solid (below 54°F) with a disagreeable, aromatic odor. [Note: A mixture typically contains 75% phenyl ether & 25% biphenyl.] |
|||
MW: 166 (approx) |
BP: 495°F |
FRZ: 54°F |
Sol: Insoluble |
VP(77°F): 0.08 mmHg |
IP: ? |
|
Sp.Gr(77°F): 1.06 |
Fl.P: 239°F |
UEL: ? |
LEL: ? |
|
Class IIIB Combustible Liquid: Fl.P. at or above 200°F. | |||
Incompatibilities & Reactivities Strong oxidizers |
Measurement Methods NIOSH 2013 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 10 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode£ (APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.£ (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin and/or eye contact | |
Symptoms Irritation eyes, nose, skin; nausea | |
Target Organs
Eyes, skin, respiratory system |
See also: INTRODUCTION |