NIOSH Pocket Guide to Chemical Hazards

Oil mist (mineral)

CAS 8012-95-1


RTECS PY8030000
Synonyms & Trade Names
Heavy mineral oil mist, Paraffin oil mist, White mineral oil mist
DOT ID & Guide

Exposure
Limits

NIOSH REL: TWA 5 mg/m3 ST 10 mg/m3
OSHA PEL: TWA 5 mg/m3
IDLH 2500 mg/m3 See: 8012951 Conversion
Physical Description
Colorless, oily liquid aerosol dispersed in air. [Note: Has an odor like burned lubricating oil.]
MW: Varies
BP: 680°F
FRZ: 0°F
Sol: Insoluble
VP: <0.5 mmHg
IP: ?

Sp.Gr: 0.90
Fl.P(oc): 380°F
UEL: ?
LEL: ?

Class IIIB Combustible Liquid: Fl.P. at or above 200°F.
Incompatibilities & Reactivities
None reported
Measurement Methods
NIOSH 5026, 5524
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: No recommendation
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily

First Aid (See procedures)

Skin: Soap wash
Breathing: Fresh air

Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 50 mg/m3:
(APF = 10) Any air-purifying respirator with an N100, R100, or P100 filter (including N100, R100, and P100 filtering facepieces) except quarter-mask respirators. Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 125 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter
Up to 250 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 2500 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, skin and/or eye contact
Symptoms Irritation eyes, skin, respiratory system
Target Organs Eyes, skin, respiratory system
See also: INTRODUCTION