Oil mist (mineral) |
CAS 8012-95-1 | ||
|
RTECS PY8030000 | ||
Synonyms & Trade Names Heavy mineral oil mist, Paraffin oil mist, White mineral oil mist |
DOT ID & Guide |
Exposure
|
NIOSH REL: TWA 5 mg/m3 ST 10 mg/m3 | ||
OSHA PEL: TWA 5 mg/m3 | |||
IDLH 2500 mg/m3 See: 8012951 | Conversion |
Physical Description Colorless, oily liquid aerosol dispersed in air. [Note: Has an odor like burned lubricating oil.] |
|||
MW: Varies |
BP: 680°F |
FRZ: 0°F |
Sol: Insoluble |
VP: <0.5 mmHg |
IP: ? |
|
Sp.Gr: 0.90 |
Fl.P(oc): 380°F |
UEL: ? |
LEL: ? |
|
Class IIIB Combustible Liquid: Fl.P. at or above 200°F. | |||
Incompatibilities & Reactivities None reported |
Measurement Methods NIOSH 5026, 5524 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: No recommendation Wash skin: When contaminated Remove: When wet or contaminated Change: Daily |
First Aid (See procedures) Skin: Soap wash Breathing: Fresh air |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 50 mg/m3: (APF = 10) Any air-purifying respirator with an N100, R100, or P100 filter (including N100, R100, and P100 filtering facepieces) except quarter-mask respirators. Click here for information on selection of N, R, or P filters. (APF = 10) Any supplied-air respirator Up to 125 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter Up to 250 mg/m3: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 2500 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin and/or eye contact | |
Symptoms Irritation eyes, skin, respiratory system | |
Target Organs
Eyes, skin, respiratory system |