NIOSH Pocket Guide to Chemical Hazards

Lindane

CAS 58-89-9

C6H6Cl6

RTECS GV4900000
Synonyms & Trade Names
BHC; HCH; gamma-Hexachlorocyclohexane; gamma isomer of 1,2,3,4,5,6-Hexachlorocyclohexane
DOT ID & Guide
2761 151

Exposure
Limits

NIOSH REL: TWA 0.5 mg/m3 [skin]
OSHA PEL: TWA 0.5 mg/m3 [skin]
IDLH 50 mg/m3 See: 58899 Conversion
Physical Description
White to yellow, crystalline powder with a slight, musty odor. [pesticide]
MW: 290.8
BP: 614°F
MLT: 235°F
Sol: 0.001%
VP: 0.00001 mmHg
IP: ?

Sp.Gr: 1.85
Fl.P: NA
UEL: NA
LEL: NA

Noncombustible Solid, but may be dissolved in flammable liquids.
Incompatibilities & Reactivities
Corrosive to metals
Measurement Methods
NIOSH 5502
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: No recommendation
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily
Provide: Quick drench
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 5 mg/m3:
(APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 12.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.*
Up to 25 mg/m3:
(APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 50 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms Irritation eyes, skin, nose, throat; headache; nausea; clonic convulsions; respiratory difficulty; cyanosis; aplastic anemia; muscle spasm; in animals: liver, kidney damage
Target Organs Eyes, skin, respiratory system, central nervous system, blood, liver, kidneys
See also: INTRODUCTION   See ICSC CARD: 0053   See MEDICAL TESTS: 0128