Lindane |
CAS 58-89-9 | ||
C6H6Cl6 |
RTECS GV4900000 | ||
Synonyms & Trade Names BHC; HCH; gamma-Hexachlorocyclohexane; gamma isomer of 1,2,3,4,5,6-Hexachlorocyclohexane |
DOT ID & Guide 2761 151 |
Exposure
|
NIOSH REL: TWA 0.5 mg/m3 [skin] | ||
OSHA PEL: TWA 0.5 mg/m3 [skin] | |||
IDLH 50 mg/m3 See: 58899 | Conversion |
Physical Description White to yellow, crystalline powder with a slight, musty odor. [pesticide] |
|||
MW: 290.8 |
BP: 614°F |
MLT: 235°F |
Sol: 0.001% |
VP: 0.00001 mmHg |
IP: ? |
|
Sp.Gr: 1.85 |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Noncombustible Solid, but may be dissolved in flammable liquids. | |||
Incompatibilities & Reactivities Corrosive to metals |
Measurement Methods NIOSH 5502 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: No recommendation Wash skin: When contaminated Remove: When wet or contaminated Change: Daily Provide: Quick drench |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 5 mg/m3: (APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters. (APF = 10) Any supplied-air respirator Up to 12.5 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.* Up to 25 mg/m3: (APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 50 mg/m3: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, nose, throat; headache; nausea; clonic convulsions; respiratory difficulty; cyanosis; aplastic anemia; muscle spasm; in animals: liver, kidney damage | |
Target Organs
Eyes, skin, respiratory system, central nervous system, blood, liver, kidneys |
See also: INTRODUCTION See ICSC CARD: 0053 See MEDICAL TESTS: 0128 |