Fibrous glass dust |
CAS | ||
|
RTECS LK3651000 | ||
Synonyms & Trade Names Fiber glas®; Fiberglass; Glass fibers; Glass wool [Note: Usually produced from borosilicate & low alkali silicate glasses.] |
DOT ID & Guide |
Exposure
|
NIOSH REL: TWA 3 fibers/cm3 (fibers with diameter < or = 3.5 µm & length > or = 10 µm.) TWA 5 mg/m3 (total) | ||
OSHA PEL: TWA 15 mg/m3 (total) TWA 5 mg/m3 (resp) | |||
IDLH N.D. See: IDLH INDEX | Conversion |
Physical Description Typically, glass filaments >3 µm in diameter or glass "wool" with diameters down to 0.05 µm & length > 1 µm. |
|||
MW: NA |
BP: NA |
MLT: ? |
Sol: Insoluble |
VP: 0 mmHg (approx) |
IP: NA |
|
Sp.Gr: 2.5 |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Noncombustible Fibers | |||
Incompatibilities & Reactivities None reported |
Measurement Methods NIOSH 7400 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: Daily Remove: No recommendation Change: Daily |
First Aid (See procedures) Eye: Irrigate immediately Breathing: Fresh air |
Important additional information about respirator selection Respirator Recommendations NIOSH Up to 5X REL: (APF = 5) Any quarter-mask respirator. Click here for information on selection of N, R, or P filters. Up to 10X REL: (APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters. (APF = 10) Any supplied-air respirator Up to 25X REL: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter. Up to 50X REL: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 1000X REL: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin and/or eye contact | |
Symptoms Irritation eyes, skin, nose, throat; dyspnea (breathing difficulty) | |
Target Organs
Eyes, skin, respiratory system |
See also: INTRODUCTION |