NIOSH Pocket Guide to Chemical Hazards

Benzoyl peroxide

CAS 94-36-0

(C6H5CO)2O2

RTECS DM8575000
Synonyms & Trade Names
Benzoperoxide, Dibenzoyl peroxide
DOT ID & Guide

Exposure
Limits

NIOSH REL: TWA 5 mg/m3
OSHA PEL: TWA 5 mg/m3
IDLH 1500 mg/m3 See: 94360 Conversion
Physical Description
Colorless to white crystals or a granular powder with a faint, benzaldehyde-like odor.
MW: 242.2
BP: Decomposes explosively
MLT: 217°F
Sol: <1%
VP: <1 mmHg
IP: ?

Sp.Gr: 1.33
Fl.P: 176°F
UEL: ?
LEL: ?

Combustible Solid (easily ignited and burns very rapidly).
Incompatibilities & Reactivities
Combustible substances (wood, paper, etc.), acids, alkalis, alcohols, amines, ethers [Note: Containers may explode when heated. Extremely explosion-sensitive to shock, heat & friction.]
Measurement Methods
NIOSH 5009
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily

First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 50 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*
Up to 125 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter.*
Up to 250 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 1500 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, ingestion, skin and/or eye contact
Symptoms Irritation eyes, skin, mucous membrane; sensitization dermatitis
Target Organs Eyes, skin, respiratory system
See also: INTRODUCTION   See ICSC CARD: 0225