Ammonium sulfamate |
CAS 7773-06-0 | ||
NH4OSO2NH2 |
RTECS WO6125000 | ||
Synonyms & Trade Names Ammate herbicide, Ammonium amidosulfonate, AMS, Monoammonium salt of sulfamic acid, Sulfamate |
DOT ID & Guide |
Exposure
|
NIOSH REL: TWA 10 mg/m3 (total) TWA 5 mg/m3 (resp) | ||
OSHA PEL†: TWA 15 mg/m3 (total) TWA 5 mg/m3 (resp) | |||
IDLH 1500 mg/m3 See: 7773060 | Conversion |
Physical Description Colorless to white crystalline, odorless solid. [herbicide] |
|||
MW: 114.1 |
BP: 320°F (Decomposes) |
MLT: 268°F |
Sol: 200% |
VP: 0 mmHg (approx) |
IP: ? |
|
Sp.Gr: 1.77 |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Noncombustible Solid | |||
Incompatibilities & Reactivities Acids, hot water [Note: Elevated temperatures cause a highly exothermic reaction with water.] |
Measurement Methods NIOSH S348 (II-5) See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: No recommendation Eyes: No recommendation Wash skin: No recommendation Remove: No recommendation Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH Up to 50 mg/m3: (APF = 5) Any quarter-mask respirator. Click here for information on selection of N, R, or P filters. Up to 100 mg/m3: (APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters. (APF = 10) Any supplied-air respirator Up to 250 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter. Up to 500 mg/m3: (APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 1500 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin and/or eye contact | |
Symptoms Irritation eyes, nose, throat; cough, dyspnea (breathing difficulty) | |
Target Organs
Eyes, respiratory system |
See also: INTRODUCTION |