The Registry of Toxic Effects of Chemical Substances
Thionyl chloride |
UPDATE: November 2004 | MW: 118.96 | MF: Cl2OS |
SYNONYMS:
|
|
|
SKIN AND EYE IRRITATION DATA AND REFERENCES:
ROUTE/ | ORGANISM
DOSE
|
| EFFECT
REFERENCE
|
N/R |
N/R
|
N/R
|
N/R
|
|
MUTATION DATA AND REFERENCES:
SYSTEM TEST
|
ROUTE/ | ORGANISM/ TISSUE
DOSE
|
REFERENCE
|
N/R
|
N/R
|
N/R
|
N/R
|
|
REPRODUCTIVE EFFECTS DATA AND REFERENCES:
ROUTE/ | ORGANISM
DOSE
|
| EFFECT
REFERENCE
|
N/R |
N/R
|
N/R
|
N/R
|
|
TUMORIGENIC DATA AND REFERENCES:
ROUTE/ | ORGANISM
DOSE
|
| EFFECT
REFERENCE
|
N/R |
N/R
|
N/R
|
N/R
|
|
ACUTE TOXICITY DATA AND REFERENCES:
ROUTE/ | ORGANISM
DOSE
|
| EFFECT
REFERENCE
|
inhalation | rat
lethal concentration (50 percent kill): 500 ppm/1 hour
|
N/R
|
NTIS** AD-A148-952
|
|
OTHER MULTIPLE DOSE DATA AND REFERENCES:
ROUTE/ | ORGANISM
DOSE
|
| EFFECT
REFERENCE
|
N/R |
N/R
|
N/R
|
N/R
|
|
REVIEWS:
ORGANIZATION
|
STANDARD
|
|
REFERENCE
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value
|
ceiling concentration 1 ppm
|
DTLVS* TLV/BEI,2003
|
|
STANDARDS AND REGULATIONS:
ORGANIZATION
|
STANDARD
|
|
REFERENCE
Occupational Exposure Limit - AUSTRALIA
|
time-weighted average 1 ppm (5 mg/m3), JAN1993
|
Occupational Exposure Limit - BELGIUM
|
short term exposure limit 1 ppm (4.9 mg/m3), JAN1993
|
Occupational Exposure Limit - DENMARK
|
time-weighted average 1 ppm (5 mg/m3, JAN1999
|
Occupational Exposure Limit - SWITZERLAND
|
MAK- week 1 ppm (5 mg/m3), JAN1999
|
Occupational Exposure Limit - UNITED KINGDOM
|
short term exposure limit 1 ppm (4.9 mg/m3), SEP2000
|
Occupational Exposure Limit - THE NETHERLANDS
|
MAC- continuous 5 mg/m3, 2003
|
Occupational Exposure Limit IN ARGENTINA, BULGARIA, COLOMBIA, JORDAN, KOREA
|
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value; | ceiling concentration 1 ppm
Occupational Exposure Limit IN NEW ZEALAND, SINGAPORE, VIETNAM
|
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value |
ceiling concentration 1 ppm |
NIOSH DOCUMENTATION AND SURVEILLANCE:
ORGANIZATION
|
STANDARD or SURVEY
|
|
REFERENCE
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Level TO THIONYL CHLORIDE-air
|
ceiling concentration 1 ppm
|
NIOSH* DHHS #92-100,1992
|
National Occupational Hazard Survey 1974
|
National Occupational Hazard Survey 1974: Hazard Code: 82024; | Number of Industries 3; Total Number of Facilities 73; Number of Occupations 7; Total Number of Employees Exposed 2,440
National Occupational Exposure Survey 1983
|
National Occupational Exposure Survey 1983: Hazard Code: 82024; |
Number of Industries 2; Total Number of Facilities 43; Number of Occupations 6; Total Number of Employees Exposed 7,082; Total Number of Female Employees Exposed 1,223 |
STATUS IN FEDERAL AGENCIES:
ORGANIZATION
|
|
REFERENCE
EPA TSCA Section 8(b) CHEMICAL INVENTORY
|
Used as specialty chlorinating agent, particularly in preparation of organic acid chlorides
|
EPA TSCA TEST SUBMISSION (TSCATS) DATA BASE, JANUARY 2001
|
|
REFERENCES:
CODEN
|
|
REFERENCE
DTLVS*
|
The Threshold Limit Values (TLVs) and Biological Exposure Indices (BEIs) booklet issues by
American Conference of Governmental Industrial Hygienists (ACGIH), Cincinnati, OH, 1996
|
NIOSH*
|
National Institute of Occupational Safety and Health, U.S. Dept. of Health, Education, and
Welfare, Reports and Memoranda.
|
NTIS**
|
National Technical Information Service. (Springfield, VA 22161) Formerly U.S. Clearinghouse
for Scientific & Technical Information.
|
|