Thiram |
CAS 137-26-8 | ||
C6H12N2S4 |
RTECS JO1400000 | ||
Synonyms & Trade Names bis(Dimethylthiocarbamoyl) disulfide, Tetramethylthiuram disulfide |
DOT ID & Guide 2771 151 |
Exposure
|
NIOSH REL: TWA 5 mg/m3 | ||
OSHA PEL: TWA 5 mg/m3 | |||
IDLH 100 mg/m3 See: 137268 | Conversion |
Physical Description Colorless to yellow, crystalline solid with a characteristic odor. [Note: Commercial pesticide products may be dyed blue.] |
|||
MW: 240.4 |
BP: Decomposes |
MLT: 312°F |
Sol: 0.003% |
VP: 0.000008 mmHg |
IP: ? |
|
Sp.Gr: 1.29 |
Fl.P: ? |
UEL: ? |
LEL: ? |
|
Combustible Solid | |||
Incompatibilities & Reactivities Strong oxidizers, strong acids, oxidizable materials |
Measurement Methods NIOSH 5005 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: Daily |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 50 mg/m3: (APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.* (APF = 10) Any supplied-air respirator* Up to 100 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 25) Any powered air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, mucous membrane; dermatitis; Antabuse-like effects | |
Target Organs
Eyes, skin, respiratory system, central nervous system |
See also: INTRODUCTION See ICSC CARD: 0757 |