NIOSH Pocket Guide to Chemical Hazards

Portland cement

CAS 65997-15-1


RTECS VV8770000
Synonyms & Trade Names
Cement, Hydraulic cement, Portland cement silicate [Note: A class of hydraulic cements containing tri- and dicalcium silicate in addition to alumina, tricalcium aluminate, and iron oxide.]
DOT ID & Guide

Exposure
Limits

NIOSH REL: TWA 10 mg/m3 (total) TWA 5 mg/m3 (resp)
OSHA PEL†: TWA 50 mppcf
IDLH 5000 mg/m3 See: 65997151 Conversion
Physical Description
Gray, odorless powder.
MW: ?
BP: NA
MLT: NA
Sol: Insoluble
VP: 0 mmHg (approx)
IP: NA

Sp.Gr: ?
Fl.P: NA
UEL: NA
LEL: NA

Noncombustible Solid
Incompatibilities & Reactivities
None reported
Measurement Methods
NIOSH 0500; OSHA ID207
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: No recommendation

First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Fresh air
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH
Up to 50 mg/m3:
(APF = 5) Any quarter-mask respirator. Click here for information on selection of N, R, or P filters.
Up to 100 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 250 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter.
Up to 500 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 5000 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, ingestion, skin and/or eye contact
Symptoms Irritation eyes, skin, nose; cough, expectoration; exertional dyspnea (breathing difficulty), wheezing, chronic bronchitis; dermatitis
Target Organs Eyes, skin, respiratory system
See also: INTRODUCTION   See ICSC CARD: 1425   See MEDICAL TESTS: 0196