Osmium tetroxide |
CAS 20816-12-0 | ||
OsO4 |
RTECS RN1140000 | ||
Synonyms & Trade Names Osmic acid anhydride, Osmium oxide |
DOT ID & Guide 2471 154 |
Exposure
|
NIOSH REL: TWA 0.002 mg/m3 (0.0002 ppm) ST 0.006 mg/m3 (0.0006 ppm) | ||
OSHA PEL†: TWA 0.002 mg/m3 | |||
IDLH 1 mg/m3 See: 20816120 | Conversion 1 ppm = 10.40 mg/m3 |
Physical Description Colorless, crystalline solid or pale-yellow mass with an unpleasant, acrid, chlorine-like odor. [Note: A liquid above 105°F.] |
|||
MW: 254.2 |
BP: 266°F |
MLT: 105°F |
Sol(77°F): 6% |
VP: 7 mmHg |
IP: 12.60 eV |
|
Sp.Gr: 5.10 |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Noncombustible Solid | |||
Incompatibilities & Reactivities Hydrochloric acid, easily oxidized organic materials [Note: Begins to sublime below BP. Contact with other materials may cause fire.] |
Measurement Methods None available See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: Daily Provide: Eyewash |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 0.1 mg/m3: (APF = 50) Any air-purifying full-facepiece respirator equipped with cartridge(s) providing protection against the compound of concern in combination with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern and having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 1 mg/m3: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern and having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, respiratory system; lacrimation (discharge of tears), visual disturbance; conjunctivitis; headache; cough, dyspnea (breathing difficulty); dermatitis | |
Target Organs
Eyes, skin, respiratory system |
See also: INTRODUCTION See ICSC CARD: 0528 |