Morpholine |
CAS 110-91-8 | ||
C4H9ON |
RTECS QD6475000 | ||
Synonyms & Trade Names Diethylene imidoxide; Diethylene oximide; Tetrahydro-1,4-oxazine; Tetrahydro-p-oxazine |
DOT ID & Guide 2054 132 |
Exposure
|
NIOSH REL: TWA 20 ppm (70 mg/m3) ST 30 ppm (105 mg/m3) [skin] | ||
OSHA PEL†: TWA 20 ppm (70 mg/m3) [skin] | |||
IDLH 1400 ppm [10%LEL] See: 110918 | Conversion 1 ppm = 3.56 mg/m3 |
Physical Description Colorless liquid with a weak, ammonia- or fish-like odor. [Note: A solid below 23°F.] |
|||
MW: 87.1 |
BP: 264°F |
FRZ: 23°F |
Sol: Miscible |
VP: 6 mmHg |
IP: 8.88 eV |
|
Sp.Gr: 1.007 |
Fl.P(oc): 98°F |
UEL: 11.2% |
LEL: 1.4% |
|
Class IC Flammable Liquid: Fl.P. at or above 73°F and below 100°F. | |||
Incompatibilities & Reactivities Strong acids, strong oxidizers, metals, nitro compounds [Note: Corrosive to metals.] |
Measurement Methods NIOSH S150 (II-3) See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet (flammable) Change: No recommendation Provide: Eyewash (>15%), Quick drench (>25%) |
First Aid (See procedures) Eye: Irrigate immediately Skin: Water flush immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH/OSHA Up to 500 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode£ (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)£ Up to 1000 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)£ (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 1400 ppm: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, nose, respiratory system; visual disturbance; cough; in animals: liver, kidney damage | |
Target Organs
Eyes, skin, respiratory system, liver, kidneys |
See also: INTRODUCTION See ICSC CARD: 0302 |