NIOSH Pocket Guide to Chemical Hazards

Cyclohexanethiol

CAS 1569-69-3

C6H11SH

RTECS GV7525000
Synonyms & Trade Names
Cyclohexylmercaptan, Cyclohexylthiol
DOT ID & Guide
3054 129

Exposure
Limits

NIOSH REL: C 0.5 ppm (2.4 mg/m3) [15-minute]
OSHA PEL: none
IDLH N.D. See: IDLH INDEX Conversion 1 ppm = 4.75 mg/m3
Physical Description
Colorless liquid with a strong, offensive odor.
MW: 116.2
BP: 316°F
FRZ: -181°F
Sol: Insoluble
VP: 10 mmHg
IP: ?

Sp.Gr: 0.98
Fl.P: 110°F
UEL: ?
LEL: ?

Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F.
Incompatibilities & Reactivities
Oxidizers, reducing agents, strong acids, alkali metals
Measurement Methods
None available
See: NMAM or OSHA Methods
Personal Protection & Sanitation (See protection)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: No recommendation
Provide: Eyewash, Quick drench
First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap flush immediately
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH
Up to 5 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)
(APF = 10) Any supplied-air respirator
Up to 12.5 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)
Up to 25 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms Irritation eyes, skin, respiratory system; headache, dizziness, lassitude (weakness, exhaustion), nausea, vomiting, convulsions; cough, wheezing, laryngitis, dyspnea (breathing difficulty)
Target Organs Eyes, skin, respiratory system, central nervous system
See also: INTRODUCTION   See ICSC CARD: 0032