2-Butoxyethanol |
CAS 111-76-2 | ||
C4H9OCH2CH2OH |
RTECS KJ8575000 | ||
Synonyms & Trade Names Butyl Cellosolve®, Butyl oxitol, Dowanol® EB, EGBE, Ektasolve EB®, Ethylene glycol monobutyl ether, Jeffersol EB |
DOT ID & Guide 2369 152 |
Exposure
|
NIOSH REL: TWA 5 ppm (24 mg/m3) [skin] | ||
OSHA PEL†: TWA 50 ppm (240 mg/m3) [skin] | |||
IDLH 700 ppm See: 111762 | Conversion 1 ppm = 4.83 mg/m3 |
Physical Description Colorless liquid with a mild, ether-like odor. |
|||
MW: 118.2 |
BP: 339°F |
FRZ: -107°F |
Sol: Miscible |
VP: 0.8 mmHg |
IP: 10.00 eV |
|
Sp.Gr: 0.90 |
Fl.P: 143°F |
UEL(275°F): 12.7% |
LEL(200°F): 1.1% |
|
Class IIIA Combustible Liquid: Fl.P. at or above 140°F and below 200°F. | |||
Incompatibilities & Reactivities Strong oxidizers, strong caustics |
Measurement Methods NIOSH 1403; OSHA 83 See: NMAM or OSHA Methods |
Personal Protection & Sanitation (See protection) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation Provide: Quick drench |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Important additional information about respirator selection Respirator Recommendations NIOSH Up to 50 ppm: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)* (APF = 10) Any supplied-air respirator* Up to 125 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)* Up to 250 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)* (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 700 ppm: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, nose, throat; hemolysis, hematuria (blood in the urine); central nervous system depression, headache; vomiting | |
Target Organs
Eyes, skin, respiratory system, central nervous system, hematopoietic system, blood, kidneys, liver, lymphoid system |
See also: INTRODUCTION See ICSC CARD: 0059 See MEDICAL TESTS: 0029 |