XENON | ICSC: 0609 |
Atomic mass: 131.3 (cylinder) CAS # 7440-63-3 RTECS # ZE1280000 UN # 2036 October 09, 1997 Peer reviewed |
TYPES OF HAZARD/ EXPOSURE | ACUTE HAZARDS/ SYMPTOMS | PREVENTION |
FIRST AID/ FIRE FIGHTING |
FIRE |
Not combustible.
Heating will cause rise in pressure with risk of bursting.
|
|
In case of fire in the surroundings: all extinguishing agents allowed.
|
EXPLOSION |
|
|
In case of fire: keep cylinder cool by spraying with water.
|
EXPOSURE |
|
|
|
INHALATION |
Simple asphyxiant.
|
Ventilation.
|
Fresh air, rest.
Artificial respiration if indicated.
Refer for medical attention.
|
SKIN |
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
Protective clothing.
|
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
Refer for medical attention.
|
EYES |
ON CONTACT WITH LIQUID: FROSBITE.
|
Safety goggles,
or face shield.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
INGESTION |
|
|
|
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Ventilation.
(Extra personal protection: self-contained breathing apparatus).
|
Fireproof if in building.
|
R: S: UN Hazard Class: 2.2 |
||
SEE IMPORTANT INFORMATION ON BACK | ||||
|
|
XENON | ICSC: 0609 |
I M P O R T A N T D A T A |
| |||
PHYSICAL PROPERTIES |
| |||
ENVIRONMENTAL DATA |
|
|||
N O T E S | ||||
High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.
Check oxygen content before entering area.
Turn leaking cylinder with the leak up to prevent escape of gas in liquid state.
|
ADDITIONAL INFORMATION | |||||
|
|
||||
|
|