CH4 Molecular mass: 16.0 (cylinder) CAS # 74-82-8 RTECS # PA1490000 UN # 1971 EC # 601-001-00-4 October 02, 2000 Peer reviewe |
TYPES OF HAZARD/ EXPOSURE | ACUTE HAZARDS/ SYMPTOMS | PREVENTION |
FIRST AID/ FIRE FIGHTING |
FIRE |
Extremely flammable.
|
NO open flames, NO sparks, and NO smoking.
|
Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out; in other cases extinguish with
water spray,
powder,
carbon dioxide.
|
EXPLOSION |
Gas/air mixtures are explosive.
|
Closed system, ventilation, explosion-proof electrical equipment and lighting.
Use non-sparking handtools.
|
In case of fire: keep cylinder cool by spraying with water.
Combat fire from a sheltered position.
|
EXPOSURE |
|
|
|
INHALATION |
Suffocation.
See Notes.
|
Ventilation.
Breathing protection if high concentration.
|
Fresh air, rest.
Artificial respiration if indicated.
Refer for medical attention.
|
SKIN |
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
|
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
Refer for medical attention.
|
EYES |
ON CONTACT WITH LIQUID: FROSTBITE.
|
Safety goggles.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
INGESTION |
|
|
|
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Evacuate danger area!
Consult an expert!
Ventilation.
Remove all ignition sources.
(Extra personal protection: self-contained breathing apparatus).
NEVER direct water jet on liquid.
|
Fireproof.
Cool.
Ventilation along the floor and ceiling.
|
F+ symbol R: 12 S: 2-9-16-33 UN Hazard Class: 2.1 |
||
SEE IMPORTANT INFORMATION ON BACK | ||||
|
|
METHANE | ICSC: 0291 |
I M P O R T A N T D A T A |
| |||
PHYSICAL PROPERTIES |
| |||
ENVIRONMENTAL DATA |
|
|||
N O T E S | ||||
Density of the liquid at boiling point: 0.42 kg/l.
High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.
Check oxygen content before entering area.
Turn leaking cylinder with the leak up to prevent escape of gas in liquid state.
After use for welding, turn valve off; regularly check tubing, etc., and test for leaks with soap and water.
The measures mentioned in section PREVENTION are applicable to production, filling of cylinders, and storage of the gas.
Other UN number: 1972 (refridgerated liquid), Hazard class: 2.1.
|