HYDROGEN SULFIDE | ICSC: 0165 |
H2S Molecular mass: 34.1 (cylinder) CAS # 7783-06-4 RTECS # MX1225000 UN # 1053 EC # 016-001-00-4 October 04, 2002 Peer reviewed |
TYPES OF HAZARD/ EXPOSURE | ACUTE HAZARDS/ SYMPTOMS | PREVENTION |
FIRST AID/ FIRE FIGHTING |
FIRE |
Extremely flammable.
|
NO open flames, NO sparks, and NO smoking.
|
Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out; in other cases extinguish with
water spray,
powder,
carbon dioxide.
|
EXPLOSION |
Gas/air mixtures are explosive.
|
Closed system, ventilation, explosion-proof electrical equipment and lighting.
Prevent build-up of electrostatic charges (e.g., by grounding) if in liquid state.
Do NOT use compressed air for filling, discharging, or handling.
|
In case of fire: keep cylinder cool by spraying with water.
|
EXPOSURE |
|
AVOID ALL CONTACT!
|
IN ALL CASES CONSULT A DOCTOR!
|
INHALATION |
Headache.
Dizziness.
Cough.
Sore throat.
Nausea.
Laboured breathing.
Unconsciousness.
Symptoms may be delayed (see Notes).
|
Ventilation, local exhaust, or breathing protection.
|
Fresh air, rest.
Half-upright position.
Artificial respiration may be needed.
No mouth-to-mouth artificial respiration.
Refer for medical attention.
|
SKIN |
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
|
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
Refer for medical attention.
|
EYES |
Redness.
Pain.
Severe deep burns.
|
Safety goggles,
or eye protection in combination with breathing protection.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
INGESTION |
|
Do not eat, drink, or smoke during work.
|
|
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Evacuate danger area!
Consult an expert!
Remove all ignition sources.
Ventilation.
Remove gas with fine water spray.
Personal protection:
gas-tight chemical protection suit including self-contained breathing apparatus.
|
Fireproof.
Separated from
strong oxidants.
Cool.
Keep in a well-ventilated room.
Install continous monitoring system with alarm.
|
F+ symbol T+ symbol N symbol R: 12-26-50 S: 1/2-9-16-36-38-45-61 UN Hazard Class: 2.3 UN Subsidiary Risks: 2.1 |
||
SEE IMPORTANT INFORMATION ON BACK | ||||
|
|