HYDROGEN CHLORIDE | ICSC: 0163 |
Hydrochloric acid, anhydrous HCl Molecular mass: 36.5 (cylinder) CAS # 7647-01-0 RTECS # MW4025000 UN # 1050 EC # 017-002-00-2 April 10, 2000 Peer reviewed |
TYPES OF HAZARD/ EXPOSURE | ACUTE HAZARDS/ SYMPTOMS | PREVENTION |
FIRST AID/ FIRE FIGHTING |
FIRE |
Not combustible.
|
|
In case of fire in the surroundings: use appropriate extinguishing media.
|
EXPLOSION |
|
|
In case of fire: keep cylinder cool by spraying with water.
|
EXPOSURE |
|
AVOID ALL CONTACT!
|
IN ALL CASES CONSULT A DOCTOR!
|
INHALATION |
Corrosive.
Burning sensation.
Cough.
Laboured breathing.
Shortness of breath.
Sore throat.
Symptoms may be delayed (see Notes).
|
Ventilation, local exhaust, or breathing protection.
|
Fresh air, rest.
Half-upright position.
Artificial respiration may be needed.
Refer for medical attention.
|
SKIN |
ON CONTACT WITH LIQUID: FROSTBITE.
Corrosive.
Serious
skin burns.
Pain.
|
Cold-insulating gloves.
Protective clothing.
|
First rinse with plenty of water, then remove contaminated clothes and rinse again.
Refer for medical attention.
|
EYES |
Corrosive.
Pain.
Blurred vision.
Severe deep burns.
|
Safety goggles
or
eye protection in combination with breathing protection.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
INGESTION |
|
|
|
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Evacuate danger area!
Consult an expert!
Ventilation.
Remove gas with fine water spray.
Personal protection: complete protective clothing including self-contained breathing apparatus.
|
Separated from
combustible and reducing substances,
strong oxidants,
strong bases,
metals
.
Keep in a well-ventilated room.
Cool.
Dry.
|
T symbol C symbol R: 23-35 S: 1/2-9-26-36/37/39-45 UN Hazard Class: 2.3 UN Subsidiary Risks: 8 |
||
SEE IMPORTANT INFORMATION ON BACK | ||||
|
|
HYDROGEN CHLORIDE | ICSC: 0163 |
I M P O R T A N T D A T A |
| |||
PHYSICAL PROPERTIES |
| |||
ENVIRONMENTAL DATA |
|
|||
N O T E S | ||||
The applying occupational exposure limit value should not be exceeded during any part of the working exposure.
The symptoms of lung oedema often do not become manifest until a few hours have passed and they are aggravated by physical effort. Rest and medical observation are therefore essential.
Immediate administration of an appropriate inhalation therapy by a doctor or a person authorized by him/her, should be considered.
Do NOT spray water on leaking cylinder (to prevent corrosion of cylinder).
Turn leaking cylinder with the leak up to prevent escape of gas in liquid state.
Other UN numbers: 2186 (refridgerated liquid) hazard class: 2.3; subsidiary hazard: 8; 1789 (hydrochloric acid) hazard class: 8, pack group II or III. Aqueous solutions may contain up to 38% hydrogen chloride.
Card has been partly updated in April 2005. See sections Occupational Exposure Limits, Emergency Response.
|
ADDITIONAL INFORMATION | |||||
|
|
||||
|
|